KNX Power Supply 640mA


KNX power supply produces and monitors system voltage.
The bus is decoupled from the power supply with the
integrated choke.
Cat. no.:UP01640

To trigger Reset – you press it for at least 22 seconds. The bus
line disconnected from the power supply and the devices
connected to this bus line are returned to their initial state.
If the line should be disconnected for a longer period, the
bus connection terminal must be removed from power
supply. A 30V DC auxiliary voltage is made available via an additional
connection terminal.

  • Power supply: 95V ~255 Vac, 47~63Hz
  • EIB/KNX nominal voltage: 30 V DC +1/–2 V, SELV + with integrated choke
  • Auxiliary voltage: 30 V DC +1/–1 V, SELV
  • EIB/KNX nominal current: 640mA, short-circuit-proof
  • EIB/KNX output: Bus connection terminal (black/red)
  • Auxiliary output: Connection terminal (yellow/grey)
  • Operation: –5 °C ~ + 45 °C
  • Storage: – 25 °C ~ + 55 °C
  • Transport: – 25 °C ~ + 70 °C
  • Mounting On DIN rail
Datasheet (pdf) available to logged in clients in SUPPORT SECTION